{"product_id":"owon-hsa2000-series-emi-oscilloscope-multimeter","title":"Owon HSA2307 - EMI Spectrum Analyser - Oscilloscope - Precision Multimeter","description":"\u003cp\u003eThe Owon HSA2000 Series is a consolidated measuring solution for the industrial environment. By integrating a \u003cstrong\u003espectrum analyser\u003c\/strong\u003e, a \u003cstrong\u003edual-channel oscilloscope\u003c\/strong\u003e, and a \u003cstrong\u003ehigh-precision 4½ digit multimeter\u003c\/strong\u003e into a single 600V CAT III chassis, it addresses the specific operational friction of diagnosing complex EMI and power quality issues in the field in a practical and economic package.\u003c\/p\u003e\n\u003cblockquote style=\"border-left: 4px solid #ccc; padding-left: 15px; font-style: italic; margin: 20px 0;\"\u003eIn industrial automation, the 'crime scene' is usually a crowded VSD cabinet or a noisy plant floor. Carrying a benchtop spectrum analyser is impractical, and a standard multimeter lacks the bandwidth to observe the issues. The HSA2000 fills that gap - affording electrical, time-base, and frequency base measurements.\u003cbr\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eEMI Investigation \u0026amp; Leakage Current Diagnostics\u003c\/h3\u003e\n\u003cp\u003eModern Variable Speed Drives (VSDs) and other power electronics are notorious for generating common-mode leakage currents that wreak havoc on analogue instrumentation, digital communications, and can cause false-triggering of emergency stops. When paired with an external current clamp (such as the \u003ca href=\"https:\/\/www.instore.nz\/products\/owon-cp024-high-frequency-ac-dc-current-probe\"\u003eOwon CP024\u003c\/a\u003e), the HSA2000 allows for high-fidelity analysis of these currents. When paired with near-field EMI probes, it allows for EMI sniffing. In an industrial environment a low-frequency H-field  (magnetic field) probe is a must-have.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eFrequency Domain (Spectrum):\u003c\/b\u003e Identify harmonic clusters and switching noise peaks from 9 kHz up to 3 GHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTime Domain (Oscilloscope):\u003c\/b\u003e Observe the exact pulse-width modulated (PWM) waveform and transients causing insulation stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEMI Sniffing:\u003c\/b\u003e Use near-field probes to locate radiated interference from poorly shielded cables or failing components before they trigger a plant-wide outage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMultimeter with 20,000-Count Precision and 600V CAT 3 Safety\u003c\/h3\u003e\n\u003cp\u003eThe HSA2000 features a 4½ digit (20,000 count) DMM. This resolution is critical for industrial technicians calibrating 4-20 mA analogue loops, testing PT100 temperature sensors, or detecting the subtle voltage drops in DC control circuits that indicate high-resistance terminations.\u003c\/p\u003e\n\u003ch3\u003eOperational Workflow \u0026amp; Documentation\u003c\/h3\u003e\n\u003cp\u003eFieldwork is only as good as its documentation. The HSA2000 provides dedicated internal storage slots for instant data capture and ease of configuration changes. There are dedicated storage arrays for the Spectrum Analyser and Oscilloscope operating modes.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e4x Configuration Slots (.BIN):\u003c\/b\u003e Instantly recall complex trigger and scale setups for repetitive testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e4x Data Slots (.CSV):\u003c\/b\u003e Export raw waveform data for post-incident analysis in Excel or Matlab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e4x Image Slots (.BMP):\u003c\/b\u003e Capture screen evidence of anomalies for maintenance reports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"border-collapse: collapse; margin-top: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"text-align: left; border-bottom: 2px solid #eee;\"\u003e\n\u003cth style=\"padding: 10px;\"\u003eFunctional Mode\u003c\/th\u003e\n\u003cth style=\"padding: 10px;\"\u003eCharacteristic\u003c\/th\u003e\n\u003cth style=\"padding: 10px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd rowspan=\"4\" style=\"padding: 10px; vertical-align: top;\"\u003e\u003cb\u003eSpectrum Analyser\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e9 kHz to 3.0 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eResolution Bandwidth (RBW)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e200 Hz to 850 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eDANL (Noise Floor)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e-140 dBm (Pre-amp On, Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e50 Ω (SMA Connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd rowspan=\"5\" style=\"padding: 10px; vertical-align: top;\"\u003e\u003cb\u003eOscilloscope (dual channel)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e70 MHz for the HSA 2307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e250 MSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eRecord Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e8K samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eVertical Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e10 mV\/div to 10 V\/div (1X Probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eProbe Ratios Supported\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1:1, 10:1, 100:1, 1000:1, 10000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd rowspan=\"3\" style=\"padding: 10px; vertical-align: top;\"\u003e\u003cb\u003eMultimeter\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e4½ Digits (20,000 Counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eV (DC\/AC), A (DC\/AC), Resistance, Cap, Diode, Continuity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eMax Voltage \/ Current\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1000V DC \/ 750V AC | 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd rowspan=\"3\" style=\"padding: 10px; vertical-align: top;\"\u003e\u003cb\u003eGeneral\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eSafety Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e600V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eBattery\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e2x 18650 - user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #eee;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eUSB HID (PC Software) \/ USB MSC (Mass Storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnectivity \u0026amp; Expansion\u003c\/h3\u003e\n\u003cp\u003eThe unit supports two distinct USB modes. \u003cb\u003eHID Mode\u003c\/b\u003e allows for real-time remote control and monitoring via the included Owon software suite—ideal for monitoring intermittent faults from a safe distance. \u003cb\u003eMSC Mode\u003c\/b\u003e treats the device as a standard storage drive for rapid file transfer.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eConfiguration Note:\u003c\/b\u003e For the ultimate portable diagnostic kit, we recommend pairing the HSA2000 with the \u003cb\u003eOwon CMS\u003c\/b\u003e—a Bluetooth-enabled clamping scope meter. This combination allows you to monitor primary current waveforms on your mobile device while performing high-resolution spectral analysis on the HSA2000.\u003c\/p\u003e","brand":"Owon","offers":[{"title":"Default Title","offer_id":46463215501483,"sku":"MEO-PM","price":1250.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0635\/6385\/8091\/files\/HSA_6.png?v=1776561972","url":"https:\/\/www.instore.nz\/products\/owon-hsa2000-series-emi-oscilloscope-multimeter","provider":"inStore Ltd","version":"1.0","type":"link"}